Tekbox TBL0550-1 LISN
The TBL0550-1 5ĀµH LISN is a device required to setup conducted noise measurements of DC-Powered electronic equipment. It is designed to be used for measurements in the frequency range of 150kHz to 110MHz according to CISPR 16-1-2, CISPR-025, EN55025, MIL-STD-461F, ISO11452-4 and with limitations DO-160/ED-14G and ISO7637-2.
The LISN is inserted into the supply line of the DUT (Device Under Test).
Conducted noise which is present at the supply terminals of the DUT can be measured at the BNC connector using a spectrum analyser or a measurement receiver. The source (supply) terminal and the DUT terminal are decoupled by a 5ĀµH inductor.
Two TBL0550-1 in combination with the Tekbox LISN Mate enable separate measurement of common mode and differential mode noise.
The unit comes equipped with a BNC-male to N-male RG232 cable, mating connectors and ground brackets to attach it to a ground plane.
Features:
- Frequency Range: 100kHz – 150MHz
- DC Resistance: <5 mĪ©
- Maximum Current: 50A Continuous, 70A for 3 minutes
- Normal Operating Voltage Range: 0-60V, DC
- Component Rating: 250V
- high current plug/screw terminals – male: Phoenix Contact 1998933, female: Phoenix Contact 1967375
- 1ĀµF capacitor can be disconnected internally by removing a jumper
- Dimensions: 120mm x 100mm x 225mm (270mm including ground brackets)
- Weight: 1.6kg