Measurement Mode | |
---|
Frequency Range | RSA3015E/RSA3015E-TG: 9 kHz to 1.5GHz RSA3030E/RSA3030E-TG: 9 kHz to 3GHz |
Reference Frequency | 10 MHz |
Accuracy | ±[(time since last calibration × aging rate) + temperature stability + calibration accuracy] |
Initial Calibration Accuracy | Standard <1 ppm Option OCXO-C08 <0.1 ppm |
Temperature Stability | 0℃ to 50℃ , with the reference 25℃ Standard <0.5 ppm Option OCXO-C08 <0.005 ppm |
Aging Rate | Standard <1 ppm/year Option OCXO-C08 <0.03 ppm/year |
Frequency | |
---|
Marker Frequency Resolution | span/(number of sweep points – 1) |
Marker Frequency Uncertainty | ±(marker frequency readout × reference frequency accuracy + 1% × span + 10% × resolution bandwidth + marker frequency resolution) |
Resolution | 1 Hz |
Uncertainty | ±(marker frequency readout × reference frequency accuracy + counter resolution) |
Range | Standard 0 Hz, 100 Hz to maximum frequency Option RSA3000-BW1 0 Hz, 10 Hz to maximum frequency |
Resolution | 2 Hz |
Uncertainty | ±span/(number of sweep points – 1) |
Carrier Offset | 1 kHz <-90 dBc/Hz (typical) 10 kHz <-100 dBc/Hz, <-102 dBc/Hz (typical) 100 kHz <-100 dBc/Hz, <-102 dBc/Hz (typical) 1 MHz <-110 dBc/Hz, <-112 dBc/Hz (typical) |
Amplitude | |
---|
Range | fc ≥ 10 MHz DANL to +30 dBm |
DC Voltage | 50 V |
CW RF Power | +30 dBm, attenuation ≥ 40 dB, preamp off. -10 dBm, attenuation = 20 dB, preamp on. |
CW RF Power | +33 dBm (2 W) |
Logarithmic Scale | 1 dB to 200 dB |
Linear Scale | 0 to reference level |
Number of Display Points | 801 |
Number of Traces | 6 |
Trace Detector | normal, pos-peak, neg-peak, sample, RMS average, voltage average, and quasi-peak (Option RSA3000-EMC) |
Trace Function | clear write, max hold, min hold, average, view, blank |
Scale Unit | dBm, dBmV, dBμV, nV, μV, mV, V, nW, μW, mW, W |
General Specifications | |
---|
Display | |
Type | capacitive multi-touch screen |
Resolution | 1024 × 600 pixels |
Size | 10.1” |
Colour | 24-bit colour |
Power | |
Input Voltage Range, AC | 100 V to 240 V (nominal) |
AC Frequency | 45 Hz to 440 Hz |
Power Consumption | 55 W (typical), max. 90 W with all options |
Environment | |
Temperature | Operating Temperature Range 0℃ to 50℃ Storage Temperature Range -20℃ to 70℃ |
Humidity | 0℃ to 30℃ ≤ 95% RH 30℃ to 40℃ ≤ 75% RH |
Altitude | Operating Height: below 3,048 m (10,000 feet) |
Specifications are liable to change. For the full list of Specifications, please see the products datasheet located under the ‘Documentation’ tab.
martin-5924 (verified owner) –
This spectrum analyser is perfect for my needs. This is my first real time SA, and I couldn’t be happier with it, the real time mode is really handy for finding those intermittent signals. The display is nice, clear and large. The touch screen is a nice feature, you can either use the touch screen or the hardware buttons to get into any of the functions of the SA, even entering frequencies, it is pretty well implemented. Mine came with the license for EMC functions which I loaded in and will be using for pre-compliance testing.