Rigol DM3068 Digital Multimeter

The Rigol DM3068 is a 6½ digit, multifunctional DMM designed for high-precision measurements. It possesses a combination of basic measurement functions, maths functions and a sensor measurement function. The 256 x 64 lattice high resolution monochrome LCD display, clear keyboard layout and built-in help facility make the DM3058E simple to use. Remote operation is possible via a choice of communications interfaces.

Features:

  • 6½ digit resolution
  • 0.0035% DC voltage accuracy
  • Various measurement speeds up to 10,000 readings/s
  • Double display function – Displays 2 measurements at once
  • DCV, DCI, ACV, ACI
  • Resistance (2 or 4 wire), capacitance, frequency, continuity and diode test
  • Sensor measurement function – Built-in thermocouple compensation
  • Supports 3 types of temperature sensor – TC, RTD & THERM
  • Various maths operations – Max, min, average, P/F, dBm, dB, relative measurement, standard deviation
  • Displays real-time trend graph and histogram
  • Internal memory stores up to 10-off system configurations & 5-off groups of sensor configurations
  • Supports the storage of configuration and data via USB flash device
  • Supports USB Device, USB Host, GPIB, RS232 & LAN
  • Supports Agilent 34401A and Fluke 45 command sets
  • Built-in Help system
  • Supplied with… Two test leads, two alligator clips, four spare fuses, USB cable, UK & European mains leads, quick guide
  • Options include… Rack mount kit, Kelvin test clips, RCL 17025 Calibration

Product Videos

Documentation

DC Characteristics

FunctionRangeTest Current or Burden Voltage1 Year 23°C ± 5°CTemperature Coefficient
0°C to 18°C
28°C to 50°C
DC Voltage200.000mV0.015 + 0.0040.0015 + 0.0005
2.00000V0.015 + 0.0030.0010 + 0.0005
20.0000V0.015 + 0.0040.0020 + 0.0005
200.000V0.015 + 0.0030.0015 + 0.0005
1000.00V0.015 + 0.0030.0015 + 0.0005
DC Current200.000μA<8mV0.055 + 0.0050.003 + 0.001
2.00000mA<80mV0.055 + 0.0050.002 + 0.001
20.0000mA<0.05V0.095 + 0.0200.008 + 0.001
200.000mA<0.5V0.070 + 0.0080.005 + 0.001
2.00000A<0.1V0.170 + 0.0200.013 + 0.001
10.0000A<0.3V0.250 + 0.0100.008 + 0.001
Resistance200.000Ω1mA0.030 + 0.0050.003 + 0.0006
2.00000kΩ1mA0.020 + 0.0030.003 + 0.0005
20.0000kΩ100μA0.020 + 0.0030.003 + 0.0005
200.000kΩ10μA0.020 + 0.0030.003 + 0.0005
2.00000MΩ1μA0.040 + 0.0040.004 + 0.0005
10.0000MΩ200nA0.250 + 0.0030.010 + 0.0005
100.000MΩ200nA / 10MΩ1.750 + 0.0040.200 + 0.0005
Diode Test2.0000V1mA0.05 + 0.010.005 + 0.0005
Continuity Test2000Ω1mA0.05 + 0.010.005 + 0.0005

AC Characteristics

FunctionRangeTest Current or Burden Voltage1 Year 23°C ± 5°CTemperature Coefficient
0°C to 18°C
28°C to 50°C
True RMS AC Voltage200.000mV20Hz – 45Hz
45Hz – 20kHz
20kHz – 50kHz
50kHz – 100kHz
1.5 + 0.10
0.2 + 0.05
1.0 + 0.05
3.0 + 0.05
0.01 + 0.005
0.01 + 0.005
0.01 + 0.005
0.05 + 0.010
2.00000V20Hz – 45Hz
45Hz – 20kHz
20kHz – 50kHz
50kHz – 100kHz
1.5 + 0.10
0.2 + 0.05
1.0 + 0.05
3.0 + 0.05
0.01 + 0.005
0.01 + 0.005
0.01 + 0.005
0.05 + 0.010
20.0000V20Hz – 45Hz
45Hz – 20kHz
20kHz – 50kHz
50kHz – 100kHz
1.5 + 0.10
0.2 + 0.05
1.0 + 0.05
3.0 + 0.05
0.01 + 0.005
0.01 + 0.005
0.01 + 0.005
0.05 + 0.010
200.000V20Hz – 45Hz
45Hz – 20kHz
20kHz – 50kHz
50kHz – 100kHz
1.5 + 0.10
0.2 + 0.05
1.0 + 0.05
3.0 + 0.05
0.01 + 0.005
0.01 + 0.005
0.01 + 0.005
0.05 + 0.010
750.000V20Hz – 45Hz
45Hz – 20kHz
20kHz – 50kHz
50kHz – 100kHz
1.5 + 0.10
0.2 + 0.05
1.0 + 0.05
3.0 + 0.05
0.01 + 0.005
0.01 + 0.005
0.01 + 0.005
0.05 + 0.010
True RMS AC Current20.0000mA20Hz – 45Hz
45Hz – 2kHz
2kHz – 10kHz
1.5 + 0.10
0.5 + 0.10
2.5+ 0.20
0.015 + 0.015
0.015 + 0.006
0.015 + 0.006
200.000mA20Hz – 45Hz
45Hz – 2kHz
2kHz – 10kHz
1.5 + 0.10
0.3 + 0.10
2.5+ 0.20
0.015 + 0.005
0.015 + 0.005
0.015 + 0.005
2.00000A20Hz – 45Hz
45Hz – 2kHz
2kHz – 10kHz
1.5 + 0.20
0.5 + 0.20
2.5+ 0.20
0.015 + 0.005
0.015 + 0.005
0.015 + 0.005
10.0000A20Hz – 45Hz
45Hz – 2kHz
2kHz – 5kHz
1.5 + 0.15
0.5 + 0.15
2.5+ 0.20
0.015 + 0.005
0.015 + 0.005
0.015 + 0.005

Note*

Specifications are liable to change. For the full list of Specifications, please see the products datasheet located under the ‘Documentation’ tab.

5 reviews for Rigol DM3068 6½ Digit Digital Multimeter

  1. Steve J

    Purchase of Rigol DM3068
    Excellent service from very helpful staff. Would happily do business again.

  2. Brian B

    Fantstic Service
    Purchased on 2 seperate occasions a

    Rigol DM3068
    Rigol DP382

    Both items are excellent, Very accurate and very well built. The service from Purchase to delivery was Very smooth and next day delivery and i received a free test meter with each purchase.

    Look forward to dealing with Teleconic again in the future….MANY THANKS GUYS

  3. Ian W

    Recent Purchase
    Excellent service ordered unit on a Friday and delivered on Monday. Everything went very smoothly

  4. Hopski

    Feature Packed!
    Brilliant multimeter. Feature Packed. Arrived in a day. Great Service from Telonic!

  5. Peter

    DM3068 Quick review
    Good value; Very quiet fan; Stabilises quickly on power up; Sturdy case; Very easy to use as a stand-alone meter (I don’t need the PC interface).

    Flaws:
    * No digital filter, and the 2 second integration time can’t cope with noisy inputs. A good filter is essential on a high resolution meter. My old Thurlby 1906 had a great programmable digital filter, and Rigol should do something similar.

    * No setup memory, so It reverts to default settings on power up (Unless you leave it on standby).

    * The display is bright and clear when viewed head-on, but if the meter is flat on a bench and you are looking down on it, the display is hard to read.

    I would have given it 5 stars if it had a proper input filter.

    Telonic Comment: Please note: The digital filter used in the Thurlby 1906 to calculate an average reading has only 10 possible settings. The integration time in the Rigol DM3068 can be set from 100us to 1s. Please refer to page 2-41 in the User Guide. Furthermore, the DM3068 has internal storage for up to 10-off user set-ups. Please refer to page 2-65 in the User Guide. Thank you for your review.

Only logged in customers who have purchased this product may leave a review.

You may also like…